Light the useful zones.
Map doors, paths and work areas. Let the layout set output, spacing and count.
Large LED wall pack lights
60W or 120W with dusk-to-dawn control. Choose the output. Price every light in your project.

Image unavailable. View official product.
More than a brighter corner
Plan the route from the entrance to the parking edge. Choose lighting for the places people use after dark.
Map doors, paths and work areas. Let the layout set output, spacing and count.
The photocell switches on at dusk and off at dawn when enabled. Verify sensor exposure.
Compare compatible packs after tier savings. Buy the project count; extras are opt-in.
Compare output, distribution, wall fit, controls and the full order—including installation costs.
No security, fixed coverage or payback guarantee. Check glare, windows and property boundaries.
01 / Choose the output your layout needs
Both: 5000K, 120° beam, 0–10V support. 120W doubles the published lumens—not necessarily usable coverage.
Several walls or buildings?
Enter the full fixture count below. Combine same-model 20-packs, 4-packs and singles.
AC 100–277V only—not 277–480V. Qualified electrician: confirm mounting, supply and 0–10V controls.
—
Continue to the product page to set package quantity, add to cart and check out.
02 / Budget for the complete fixture order
Enter your layout’s fixture count. Compare compatible packs after eligible subtotal savings.
120W · project estimate
Default: no extra fixtures. The estimate never mixes 60W and 120W, and never adds anything to your cart.
Fixtures only. Excludes tax, shipping, electrical work, wall preparation, installation and accessories not in the selected package.
Enter your required fixture count.
Open every line and set its package quantity before adding to cart. This page does not transfer the whole plan.
More than 40 fixtures? Request a volume quote and confirm lead time on the product page.
Savings are an estimate under the displayed rules. Confirm eligibility and stock at checkout. No other offer is stacked.
USD only. The highest reached threshold applies once to the whole eligible merchandise subtotal after multipack pricing, before tax and shipping.
Use the product selectors above for current package prices. Enable JavaScript for a complete package estimate.
03 / See the evidence
Original day/night images, hardware video and a selected-model review. Inspect the sources.

Image unavailable. Open the source gallery below.

Image unavailable. Open the source gallery below.
Shared brand pair; wattage/location unknown. Viewpoint, daylight and exposure differ. Application example—not a measured before/after or coverage guarantee.
View original day/night comparison ↗Official shared wall-pack video · about 1:08 · housing and LED hardware close-up. Exact wattage is not identified; not a selected-model coverage test. No autoplay.
Video unavailable here. Open the original video link.
Open original video ↗Start with the part of the building
Map the path to each door, wall mounting positions and nearby windows. Match output to the route and glare limits; the 120° beam does not establish a fixed spacing or coverage area.
Supply and control: hardwired AC 100–277V and compatible 0–10V control wiring. Mounting and sealing: junction-box fit, wall condition and sealing per the supplied manual; silicone sealant is not included. Photocell: the linked manual says its opaque cap must be removed to enable dusk-to-dawn operation. Have a qualified electrician verify these details and applicable requirements.
Compare the two large wall packs
Published sheet values—not a measured coverage test. Swipe to compare.
| Decision point | 60W large wall pack | 120W large wall pack |
|---|---|---|
| Fixed output | 7,800 lm | 15,600 lm |
| Efficacy | 130 lm/W published | 130 lm/W published |
| Housing dimensions | 312 × 175 × 137.5 mm | 364 × 233 × 163 mm |
| CCT / beam | 5000K / 120° | 5000K / 120° |
| Controls | Photocell + 0–10V support | Photocell + 0–10V support |
| Supply / ingress | AC 100–277V / IP65 | AC 100–277V / IP65 |
| Current package sizes | 1 / 4 / 20 fixtures | 1 / 4 / 20 fixtures |
| How to choose | When the layout calls for 7,800 lm and the smaller housing. | When the layout calls for more output and the larger housing fits—not merely because more watts are available. |
These are separately sourced products—not alternate names for the large wall pack. They are not mixed into this page's budget.
| Format | What differs | Source product |
|---|---|---|
| Large wall pack | 60W / 120W · wide 120° beam · 0–10V support | Use the model selector above. |
| Adjustable full-cutoff | 100W example · 14,000 lm · 90° × 65° beam · 0–90° head adjustment · AC 100–277V | Check separate full-cutoff model ↗ |
| Mini wall pack | 30W example · 3,600 lm · AC 120V only · photocell · non-dimmable | Check separate mini model ↗ |
Distribution, aim and local requirements determine glare and light spill. “Full-cutoff” is the manufacturer's product description, not a DarkSky certification claim or a guarantee at every aim angle.
Selected model specifications
Output, dimensions, SKU and the corresponding technical-sheet page update with the selection.
120W large LED wall pack
| Selected SKU | See selected package |
|---|---|
| Fixed power / output | 120W / 15,600 lm published |
| Efficacy / CCT / beam | 130 lm/W published / 5000K fixed / 120° |
| Supply | AC 100–277V; installation manual lists 50/60Hz |
| Controls | Integrated dusk-to-dawn photocell; 0–10V dimming with compatible control and correct wiring |
| Dimensions W × H × D | 364 × 233 × 163 mm |
| Housing | Bronze powder-coated die-cast aluminum |
| Mounting | Wall / junction-box mount. Verify box pattern, surface and electrical installation. Seal per supplied instructions. |
| Ingress | IP65 published; damp/wet locations per linked manual after correct mounting and sealing. Not submersible or a washdown approval. |
| Ambient temperature† | Technical sheet: −40°C to 40°C (−40°F to 104°F). Manual and product graphic differ; confirm the supplied-model limit. |
| Published marks† | Technical sheet displays UL / DLC / FCC / RoHS marks. Exact fixture listing and rebate eligibility must be verified. |
| Life / warranty | 50,000-hour rated-life claim / 5-year limited warranty, subject to current terms. Rated life is not a warranty duration. |
Official sheet, 120W page 2. Reviewed October 9, 2026.
Sheet: UL / DLC / FCC / RoHS marks. Product comparison: ETL / CE / RoHS. Confirm the exact label and certificate with JC-LGL; no rebate or approval promised.
Temperature: sheet −40°C to 40°C; manual −35°C to 50°C; graphic −22°F to 122°F. Confirm the supplied-model limit. No unconditional “all-weather” claim.
Some shared 60W gallery assets say 120W. This guide uses each model's own main photo and sheet page; prices use current numeric variant data.
Why choose JC-LGL?
Both outputs offer photocell operation and 0–10V dimming support.
Current pack prices, a compatible checklist and estimated tier savings.
Original imagery, hardware video, corresponding technical-sheet pages and a published 5-year limited warranty.
Common purchase questions
No. Match output to the layout and glare constraints. 120W uses more power and a larger housing; efficacy, CCT and control support are shared.
No. The photocell responds to ambient light, not movement. These main products are not being sold here as motion-sensor or app-controlled fixtures.
Open each line and set its package quantity on the product page. Verify combined count and savings at checkout; no automatic cart transfer.
No. These models list AC 100–277V input. Have a qualified electrician verify the actual supply and select suitable equipment for other voltage systems.
Light the building. Plan the order.
Continue with the selected package or review your complete purchasing checklist.
JC-LGL LIGHTING STUDIO
Plan indoor and outdoor LED lighting with JC-LGL fixtures across 24 scenes. Set dimensions in feet, drag up to 100 fixtures into place, and compare estimated illuminance and power.
Looking for 3D lighting simulation design? Please visit JC-LGL 3D Lighting Studio to view recommended lamps for different scenarios, lamp placement, 3D lighting effects, and plan for saving the scheme.